Free tools / Scuba calculators

Free scuba calculator

Nitrox best mix calculator

Free nitrox best mix calculator. The richest whole-percent oxygen mix for a planned scuba depth and PO2, rounded down and capped at the recreational range.

For planning and education only. Not a substitute for training, certification limits, or a dive computer.

Calculate best mix

Units

Water

1.4 is the usual recreational working limit.

Best mix, rounded down

35%

Unrounded 35%. Rounded down 35%.

MOD of this mix at your PO2: plan no deeper than 30 m.

What best mix means

Best mix is the richest oxygen percent that stays at your PO2 limit at the deepest depth you plan to hit. Richer oxygen means less nitrogen, which is why people ask for it. It also means a shallower maximum operating depth. The mix and the depth are the same decision seen from two sides.

PADI describes recreational nitrox as 22% to 40% oxygen. NOAA's diving standards use that same range and a maximum PO2 of 1.40 ATA on the working dive. This calculator rounds the ideal percent down to a whole number, then stops at 40% when the math wants something richer. The uncapped whole percent stays on screen so you can see the cap working. Mixes above 40%, and anything below air, are outside this tool.

A best-mix number is not a fill ticket. Analyze the cylinder and run the MOD on the analyzed percent before you splash. The EAD calculator is what you use afterward if the plan still goes through an air table.

Formula and a worked example

Absolute pressure is depth / 10 + 1 in seawater meters, or depth / 33 + 1 in feet. Fresh water uses 10.3 m or 34 ft. Best mix is the PO2 divided by that pressure.

ATA = depth / 10 + 1

Ideal oxygen % = PO2 / ATA x 100

Best mix = that percent, rounded down to a whole number

Recreational cap = 40%

30 m of seawater at a PO2 of 1.4 is 4.0 ATA. 1.4 / 4.0 = 0.35, so the best mix is 35%. It is already a whole percent, and it is inside 22% to 40%.

28 m is 3.8 ATA. 1.4 / 3.8 x 100 = 36.8%, which rounds down to 36%. The next percent, 37%, would put the PO2 over 1.4 at 28 m. EAN36 at 1.4 has a calculated MOD of 28.9 m and a planning depth of 28 m, so 28 m is on the rounded-down side of that limit. That is why the mix rounds down.

If the rounded percent is above 40, the recommendation stays at 40 and the higher number is labeled uncapped. If it is below 21, air itself is past the PO2 and this page stops. It will not invent a hypoxic bottom gas.

Common mistakes

Rounding up because 36.8 looks closer to 37. At the planned depth, 37 can be the mix that crosses the PO2 line.

Diving a capped 40% mix deeper than the MOD of 40%. The cap does not make 40% safe at every depth. Read the MOD line under the result.

Asking the station for the calculated percent and never analyzing. The MOD you dive is the one for the gas you measured.

Using this number as a decompression plan. It is an oxygen fraction for a single depth. Time, stops, and gas switches are a different course and are not calculated here.

Sources

Questions

What is the best nitrox mix?
For a planned depth and a maximum PO2, the best mix is the highest oxygen percent that keeps you at that PO2 limit. A richer mix leaves less nitrogen. This calculator rounds that percent down to a whole number so the PO2 does not go over the limit.
Why round the best mix down?
Oxygen fraction times absolute pressure is the PO2. Rounding the mix up can push the PO2 over the limit you set. Rounding down keeps the mix at or under it. The page also shows the unrounded percent so you can see what was discarded.
Why is the result capped at 40%?
PADI describes recreational nitrox as 22% to 40% oxygen, and NOAA's diving standards use the same 22% to 40% range for nitrox. If the math is richer than 40%, the recommendation stays at 40% and the uncapped whole percent is shown beside it. Mixes above 40% need further training and oxygen-clean equipment.
What if the result is below 21%?
Then air itself would exceed your PO2 at that depth. This calculator does not recommend a hypoxic mix. That is technical diving, often with helium, and it is outside this tool.
Can I tell the fill station this percent and skip the analyzer?
No. The percent you asked for and the percent in the cylinder can differ. Analyze the fill, then run the MOD for the analyzed mix before you dive it.
  • Scuba calculators. Nitrox MOD, equivalent air depth, best mix, SAC rate, and a starting weight estimate. Free, in the browser.
  • Nitrox MOD calculator. Maximum operating depth from the oxygen percent and a maximum PO2. Defaults to 1.4, with the 1.6 contingency.
  • EAD calculator. Equivalent air depth for a nitrox mix at a planned depth, in meters or feet.
  • SAC rate calculator. Surface air consumption and RMV from pressure used, tank size, depth, and time, plus how long a tank lasts.
  • Scuba weight calculator. A starting weight estimate from body weight, exposure suit, salt or fresh water, and tank type. Check it in the water.